Results You searched for: Tube Welding Results Displayed: 1 - 1 of 1
TSCD® II Sterile Tubing Welder
Increase the Productivity of Your Laboratory With Reliable, Sturdy Welds
Designed for quality, reliability and flexibility, the TSCD-II welder is a next-generation, closed-system device that can be used to connect polyvinyl chloride (PVC) tubing in any combination of wet and dry.
The wafers used by the TSCD-II welder heat up to 300°C, maintaining sterility during cutting and welding without allowing particulates or chemical residue to form in the tubes. The design enables fast, one-handed operation, and durable materials stand up to intensive use.
Outer Diameter: 03.86 mm–04.60 mm 0.152 in–0.181 in
Wall Thickness: 0.508 mm–0.800 mm 0.019 in–0.031 in
Wafer
TSCD Wafer (TRM-1SCW017)
Power Supply
AC 100 V–AC 240 V, 3A 50–60 Hz
External Dimensions W x H x D
224 mm x 177 mm x 342 mm 9 in x 7 in x 13 in
Weight
Approximately 6.5 kg (14.33 lbs)
Weld Cycle
Approximately 1 weld every 14 seconds
Accessories
AC power cable, bag supports, fuses (250V/4.0A), cassette of TSCD wafers and operating instructions
OPERATING CONDITIONS
Instrument should be allowed to equilibrate at these conditions before use
Ambient Temperature
10°C to 40°C (50°F to 104°F)
Humidity
10% to 80%, RH non-condensing
Altitude
Up to 3,658 m maximum (12,000 ft)
STORAGE CONDITIONS
Ambient Temperature
-10°C to 50°C (14°F to 122°F)
Humidity
10% to 95%, RH non-condensing
TSCD® II Sterile Tubing Welder
Increase the Productivity of Your Laboratory With Reliable, Sturdy Welds
Designed for quality, reliability and flexibility, the TSCD-II welder is a next-generation, closed-system device that can be used to connect polyvinyl chloride (PVC) tubing in any combination of wet and dry.
The wafers used by the TSCD-II welder heat up to 300°C, maintaining sterility during cutting and welding without allowing particulates or chemical residue to form in the tubes. The design enables fast, one-handed operation, and durable materials stand up to intensive use.
Copyright, Terumo BCT, Inc. 2017
Maintains a closed system
Joins any combination of tubing: wet-to-wet, dry-to-dry, wet-to-dry
Provides automatic wafer replacement
Features an interconnected clamp for one-handed operation
Guides use and displays process on the screen
Detachable shelves for bag support
Reduces the risk of jams with a wafer monitor and a large used-wafer disposal box
Creates welds that meet or exceed the tensile strength requirements of ISO 3826-1
/Customer/esscin/specpages/TSCDII.pdfTSCD II Brochurehttps://www.terumobct.com/tscd-IITerumo BCT
Maintains a closed system
Joins any combination of tubing: wet-to-wet, dry-to-dry, wet-to-dry
Provides automatic wafer replacement
Features an interconnected clamp for one-handed operation
Guides use and displays process on the screen
Detachable shelves for bag support
Reduces the risk of jams with a wafer monitor and a large used-wafer disposal box
Creates welds that meet or exceed the tensile strength requirements of ISO 3826-1
/Customer/esscin/specpages/TSCDII.pdfTSCD II Brochurehttps://www.terumobct.com/tscd-IITerumo BCT
MODEL
3ME-SC203A
Tubing Material
Polyvinyl Chloride (PVC)
Tubing Size blood bag type tubing
Outer Diameter: 03.86 mm–04.60 mm 0.152 in–0.181 in
Wall Thickness: 0.508 mm–0.800 mm 0.019 in–0.031 in
Wafer
TSCD Wafer (TRM-1SCW017)
Power Supply
AC 100 V–AC 240 V, 3A 50–60 Hz
External Dimensions W x H x D
224 mm x 177 mm x 342 mm 9 in x 7 in x 13 in
Weight
Approximately 6.5 kg (14.33 lbs)
Weld Cycle
Approximately 1 weld every 14 seconds
Accessories
AC power cable, bag supports, fuses (250V/4.0A), cassette of TSCD wafers and operating instructions
OPERATING CONDITIONS
Instrument should be allowed to equilibrate at these conditions before use